Sime SOLO 20 OF Instrucciones Para El Instalador página 80

Ocultar thumbs Ver también para SOLO 20 OF:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
along its travel. This will keep both
outlets, heating and sanitary, par-
tially open.
4.4
DISASSEMBLY
OF OUTER CASING
The. shell. can. be. completely. disas-
sembled.for.an.easy.maintenance.of.
the. boiler. by. following. the. numeric.
steps.shown.in.fig..14.
4.5
DISASSEMBLY
OF EXPANSION
VESSEL
.
The.heating.expansion.tank.is.disas-
sembled.in.the.following.manner:
–..Make. sure. that. the. boiler. has.
been.emptied.of.water.
–..Unscrew. the. union. which. con-
nects.the.expansion.tank.
–..Remove.the.expansion.tank.
Before. filling. up. the. system. make.
sure. that. the. expansion. tank. is.
reloaded. at. the. pressure. of. 0.8. ÷. 1.
bar.
4.6
BURNER MAINTENANCE
To. dismantle. the. burner. from. the.
boiler.door,.remove.the.nut.(fig..15).
–. To.access.the.internal.part.of.the.
burner,. remove. the. air. lock. unit.
held. in. place. by. two. screws. to.
the. sides. and. remove. the. right.
hand.shell,.which.is.held.in.place.
by.four.screws,.taking.care.not.to.
damage.the.O-ring.seal..OR.
–. To. dismantle. the. nozzle. holder.
and. heater. unit,. proceed. as. fol-
lows:
–. open.the.cover,.which.is.held.in.
place. by. a. screw,. and. remove.
the. heater. cables. (1. fig.. 15/a).
protected. by. a. heat. resistant.
sheath;.remove.the.fairlead.and.
pass. the. cables. through. the.
hole.
–. remove.the.two.cables.from.the.
ignition. electrodes. fastened. in.
place.with.a.faston.
–. loosen.the.union.(2.fig..15/a).and.
remove. the. four. screws. which.
fasten. the. collar. (3. fig.. 15/a). to.
the.burner.
–. To. dismantle. the. eater. or. ther-
mostat,.refer.to.figure.15/b.
78
4
5
2
1
3
KEY
. 1. Control.bow.cables
. 2. Connection
. 3. Collar
2
6
3
1
Fig..14
Fig..15
Fig..15/a
Tabla de contenido
loading