Installation, Operating and
Maintenance Instructions
EN
3
Figure 3.2-3: Detail
T-KÜ-T1 FT without
cover plate
Figure 3.2-4: Cable assignment when used with blueMatic EAV
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMatic EAV
• Install the cable for example within the
• Complete the plug-in connection after
• Fix the sash part
Caution! Release the second retaining screw
installation of the door frame into the reveal) when unhinge the
door sash! Insulate the wires not used!
Wire
glazing chamber towards the motor housing;
install the rest of the cable for example within
the hollow section.
Caution! Provide cable reserve of
about 3 - 5 cm for the spring tension
behind the sash part
transition!
putting the door on its hinges
Ø 3 x 20 mm (Figure 3.2-1)
Cable assignment when
used with blueMatic EAV
white
+ 12 V DC
brown 0 V (ground)
green
Release signal
yellow optional, for swing door
opener
grey
optional, for swing door
opener
pink
not assigned
40
5044744
of the cable
with the fitting screw
(e.g. during the
Neces-
sary
yes
yes
yes
yes
yes
no