INSTALLATION REQUIREMENTS
Your air conditioner will install into standard double
hung windows with actual clear opening widths of
25 to 36 inches (635mm to 914mm) (FIG. 1).
Lower sash must open sufficiently to allow a clear
vertical opening of 14 inches (356mm). Side louvers
and the rear of the air conditioner must have clear
air space to allow enough airflow through the
condenser for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
Interiorwall "-....
"
Sill
FIG. 1
ELECTRICAL
SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate(found on right side of
cabinet).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for
future reference. The carton is the best way to store
unit during winter or when not in use.
INSTALLATION
HARDWARE
FIG. 2
NO.
NAME OF PARTS
Q'TY
1
SIDE CURTAIN
2
2
SILL SUPPORT
2
3
BOLT
2
4
NUT
2
5
SCREW(TYPE
A) : 25/64"
16
6
SCREW(TYPE
B) : 5/8"
3
7
SCREW(TYPE
C) : 5/8"
5
8
FOAM SEAL
1
9
UPPER GUIDE
1
10
FOAM - PE
1
11
FOAM - PE
1
12
WINDOWLOCKINGBRACKET
1
To avoid risk of personal injury, properly damage,
or product damage due to the weight of this device
and sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people are
needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
• Carefully inspect location where air conditioner
will be installed.
Be sure it will support the weight of the unit over
an extended perior of time.
• Handle air conditioner with care. Wear protective
gloves whenever lifting or carrying the unit.
AVOID the sharp metal fins of front and rear coils.
• Make sure air conditioner does not fall during
installation.
REQUIRED TOOLS;
• Tight Fitting gloves
° Pliers
• 3/8-inchopen end wrench
° Tape measure
Standard screwdriver
• Sharp knife
° or adjustablewrench
• Electric drill
Phillips screwdriver
° Carpenters level
1/4-inch hex socket
• 1/4-inch drille bit
and ratcher
-5-