Operation; Safety Notes; Operating Conditions; Operation/Use - SystemAir Multibox MUB Serie Instrucciones De Montaje Y Servicio

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
9

Operation

9.1

Safety notes

WARNING
Hazard from electrical voltage
The device may only be operated by people
instructed in the function and risks,
who have understood them and are in a position to react accordingly.
Ensure that children do not operate the device or play with it without supervision.
Ensure that only people who are in a position to operate the device safety have access to it.
9.2

Operating conditions

Do not operate the Multibox in an explosion-capable atmosphere.
During operation, touching the rotor may not be possible.
Safety components may not be circumvented or put out of function.
Please only operate the multibox within the limits stated on the name plate.
Prevent suction of foreign bodies, this can destroy the fan.
Switching frequency::
The Multibox has been admitted for S1 long-term operation.
The controls may not permit any extreme switching operations.
In cases of speed control via frequency inverters, make sure that voltage peaks on the motor terminals must be lower than 1000 V
and voltage rise velocities lower than 500V/µs (IEC 34-17).
If the motor line is long, use an output filter between the frequency inverter and the motor.
If the operational leakage current of 3.5 mA is exceeded, the conditions with a view to earthing pursuant to DIN VDE 0160/5.88.
ART.6.5.2.1 are to be fulfilled.
Noise development can be minimised by use of a noise filter.
9.3

Operation/use

Only use the Multibox in accordance with the operating instructions and the operating instructions for the motor.
"
During operation, monitor the Multibox for correct function.
"
Switch the Multibox off as planned:
"
WARNING
Danger from electrical voltage or parts flying through the air
Errors occurring can lead to personal or property damage
Switch the Multibox off as planned:
in cases of atypical running noises, vibrations, pressure fluctuations
if the values for current, voltage and temperature are exceeded (name plate).
45
Tabla de contenido
loading

Este manual también es adecuado para:

Multibox mub ulMultibox mub/tMultibox mub/fMultibox mub-ec

Tabla de contenido