EVVO INTENSA RETRO Manual De Instrucciones página 30

Idiomas disponibles

Idiomas disponibles

ENGLISH
12. Brewing Time Setting Function
brewing time according to your demand.
1. To adjust the single cup amount, press and hold the "single-cup button" for 3
seconds,the machine beep 3 times and start to brewing.
2. To adjust the double cup amount, press and hold the "double-cups button" for 3
seconds,the machine beep 3 times and start to brewing.
When the coffee in the cup reaches the required set amount, press the "Single-cup
or double-cup coffee button" to stop brewing. Machine beep three times, indicating
that amount has been set and the next coffee discharging time will follow the last set
value.
NOTE: Coffee brewing time is set between 8-60 seconds; otherwise, the setting is
failed.
13. Coffee temperature selection function
1. Press the "On/Off button", the machine starts to preheat automatically. Once the
main menu of program settings.
Single-cup light on = Low temperature coffee brewing mode
Double cup light on = Middle temperature coffee brewing mode (Default mode)
Steam light on = High temperature coffee brewing mode
4. Press the corresponding button above according to the temperature mode you,
for 3 times,the temperature set successfully and return to brewing coffee state.
NOTE: If there is no any operation within 15S, machine will exit program setting and
30
CAFETERA ESPRESSO EVVO INTENSA RETRO
loading

Productos relacionados para EVVO INTENSA RETRO

Este manual también es adecuado para:

V0165V0166V0169