Brandt BPG3400W Guía De Instalación Y Uso página 35

Placa de gas
Idiomas disponibles

Idiomas disponibles

10) REPLACING THE INJECTORS
The burners can be adapted to different types of gas by mounting injectors suited to the type of gas in
question. To do this, first remove the burner tops using a an appropriate tool. Now unscrew injector (see fig.
12 - 12/A) and fit a injector corresponding to the utilized type of gas in its place.
It is advisable to strongly tighten the injector in place.
After the injectors have been replaced, the burners must be regulated as explained in paragraphs 9. The
technician must reset any seals on the regulating or pre-regulating devices.
The envelope with the injectors and the labels can be included in the kit, or at disposal to the authorized
customer Service Centre.
For the sake of convenience, the nominal rate table also lists the heat inputs of the burners, the diameter of
the injectors and the working pressures of the various types of gas.
BURNERS
DESCRIPTION
RAPID
1
SEMIRAPID
2
AUXILIARY
3
*In accordance with Regulation No. 66/2014 EU measures for the implementation of Directive 2009/125/EC, the
performance (EEgas burner) was calculated according to EN 30-2-1 last review with the G20.
CONVERSIONS
NORMAL
PRESSURE
GAS
mbar
G30 - BUTAN
28 - 30
G31 - PROPAN
37
G20 - NATURAL
20
G30 - BUTAN
28 - 30
G31 - PROPAN
37
G20 - NATURAL
20
28 - 30
G30 - BUTAN
37
G31 - PROPAN
G20 - NATURAL
20
TABLE
NORMAL
INJECTOR
RATE
DIAMETER
gr/h
l/h
1/100 mm
204
83
200
83
117 S
267
127
65
125
65
167
97 Z
73
50
71
50
95
72 X
NOMINAL HEAT
INPUT (W)
Min.
Max.
E.E
Gas Burner*
900
2800
55.1%
900
2800
900
2800
550
1750
55.1%
550
1750
550
1750
450
1000
450
1000
N.A.
450
1000
33
loading

Este manual también es adecuado para:

Bpg3400bBpg3400bmBpg3200b1074582