11.1 Technical data
 "m.v." means a standard measured value.
True RMS measurement for AC current
Range
40.00 A
400.0 A
All AC current ranges are specified from 5% to 100% of range
Frequency range: 50 Hz...60 Hz
Overload protection: 400 A
DC current measurement
Range
40.00 A
400.0 A
Overload protection: 400 A
True RMS voltage and VFD measurement
Range
Resolution
4.000 V
0.001 V
40.00 V
0.01 V
400.0 V
0.1 V
1000 V
All AC voltage ranges are specified from 5% to 100% of range
Input impedance: 10 MΩ
Frequency range: 50 Hz...1000 Hz
Overload protection: 1000 V DC/AC RMS
AC voltage range for VFD function: 100 V...600 V
62
11 Specifications
Resolution
0.01 A
0.1 A
Resolution
0.01 A
0.1 A
for f = 50 Hz...60 Hz
(all waveforms)
 (1.2% m.v. + 5 digits)
 (1.5% m.v. + 5 digits)
1 V
CMP-402 ● CMP-403 – USER MANUAL
 (2.0% m.v. + 8 digits)
 (2.5% m.v. + 8 digits)
 (2.0% m.v. + 8 digits)
 (2.5% m.v. + 8 digits)
Accuracy
Accuracy
Accuracy
Accuracy
for f = 50 Hz...1 kHz
(sine waveforms)
 (1.2% m.v. + 5 digits)
 (1.5% m.v. + 5 digits)