The indicator light I1 on indicates that the antigrease filter
is saturated, while the indicator light I2 on indicates that the
odour filter is saturated (for hoods in filtering mode only).
Press T5 + T4 for 3 seconds with the hood on to reset the
counter.
Hood type setting
The hood can be set to the ventilation (default) or filtering
mode. To change the setting proceed as follows:
• with the hood OFF, the menu is accessed by pressing the
T4 e T5 buttons for a prolonged time; this is signalled by
a sound emitted by the hood and by the I4 icon lighting
up and the writing C1-0 appearing on the display;
• use the buttons T4 and T5 to go through the menu. Use
T4 to go through the various menu items (C1, C2, C3,
C4, etc) and T5 to select them (0, 1 or 0, 1, 2);
• to set the hood type, access the menu, select the item
C6 with T4 and set the value 0 with T5 to set the hood
on ventilation mode or 1 for the filtering mode. Press T1
at the end.
Hood off
The hood can be turned off manually by pressing the T1
button (ON/OFF). If the hood stays on in manual mode, it
turns off automatically after a certain "safety" time. If the
timer is set, the hood turns off automatically when the set
time runs out.
Models with Touch control glass + display
(high)
HLQB 9.8 LSHSI X/HA - HLQB 9.8 LSHI X/HA
T1 T2 T3 T4
T1 motor ON/OFF
When the button is pressed with the hood off, the first speed
is set. When the button is pressed during operation, the
hood switches OFF.
T2 Speed –
When the button is pressed the hood switches to the
previous speed.
T3 Speed +
When the button is pressed the hood switches to the next
speed. If the hood is off, speed 1 is set when pressing this
button.
T4 Booster
When the button is pressed, the hood switches from the
previous status to the intensive speed; the letter "b" will flash
slowly on the display. The setting has a limited timeframe;
when the time elapses the hood goes back to the speed set
previously; when a speed button is pressed (T2, T3 or T4),
the selected speed is set as you leave the booster mode.
T5 AUTO
Press the T5 button to activate the automatic mode, which
turns the hood on based on the steam level detected. While
in normal operation the sensor regulates the motor speed
within the admitted values (0,1,2,3 or booster). The hood
switches from automatic to manual mode when the Booster
or Speed button is pressed.
The sensor needs calibrating before use; for more
information please refer to paragraph "Calibration
procedure"
T6 Timer "–"
With the timer, a time can be set, after which the hood
turns OFF; if the timer is set and the speed is subsequently
changed by pressing T2, T3 or T4, the timer is deactivated.
Press the T6 button to decrease the previously set value
by 5 minutes.
T7 Timer "+"
When the button is pressed for the first time, the timer is set
to 5 minutes; this value is increased by 5 additional minutes
every time the button is pressed after that.
T8 lights ON/OFF
It turns the work lights of the hood on and off.
D1: DGT Speed
D2: Assembly of 2 DGT Time
I1: Grease Filter Indicator
T5 T6 T7 T8
I2: Carbon Filter Indicator
I4: Menu Indicator
I5: Timer Indicator
Antigrease and odour filter signal
The antigrease (A) and odour (B) filters need cleaning/
replacing after a certain number of hours of use (the latter
for filtering hoods only).
The indicator light I1 on indicates that the grease filter is
saturated, while the indicator light I2 on indicates that the
odour/carbon filter is saturated (for hoods in filtering mode
only).
Press T5 + T6 for 3 seconds with the hood on to reset the
counter.
Automatic sensor calibration procedure
- Calibration: the calibration procedure must be carried
- Automatic calibration: occurs when the hood is power
I1
D1
I2
out in a clean environment to be effective; therefore, the
hob must be off during the calibration.
During the calibration procedure the AUTO button is on
and the AUTO writing flashes on the display.
The sensor calibration may be automatic or manual
("upon request"). In both cases the calibration lasts:
• about 1 minute for gas hobs;
• about 13 minutes for induction and electric hobs.
supplied or after selecting the plan from the configuration
menu.
GB
D2
I5
I4
31