CookMax 90633005 Manual De Empleo página 93

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 101
In the event that another alarm event were to occur, for high or low temperature, if the information relative to the
preceding anomaly hasn't been visualised by the operator, this latter will be overwritten by the more recent data.
If the high temperature alarm is on, the compressor keeps working; if the low temperature alarm is on, the
compressor stops.
! If the card is set to the stand-by mode, the min. / max. temperature memorized and any alarms will
not be saved
.
BLACKOUT ALARM
OPEN DOOR ALARM
In case of door open the display visualises the message [dA] alternating with the current visualisation whilst
the buzzer sounds the event with a beep of five seconds repeated every 10.
The alarm will reset upon the closure of the door and is registered in memory (high frequency flashing
defrost LED).
HIGH CONDENSATION TEMPERATURE ALARM
If the condensation temperature is too high, due to dirty condenser, the label [HtC] and the room temperature
alternate on the display.
The buzzer sounds.
The buzzer can be turned off by pressing the key
The visual warning signal stays on until the condensation tempertaure returns to normal range.
HIGH PRESSURE ALARM
If the refrigerating appliance pressure is above the specified limit, the label [HP] and the room temperature
alternate on the display.
The buzzer sounds.
The buzzer can be turned off by pressing the key
The visual warning signal stays on until the card is set to stand-by.
! If the problem causing the alarm reoccurs on restarting the system, the signal [HP] will be displayed again.
In this case, all the relay outputs are de-activated except the condenser fan output.
Pushing the enter button the time duration of alarm event, expressed in
minutes, will be visualised on the flashing display.
Pushing the enter button the operation of the defrost LED will be reset to its
normal state.
The display shows [rES] after the abnormal event.
The defrost led blinking at high frequency indicates a blackout
Pushing the enter button the [bLO] label will be visualised on the display.
Pushing the enter button the maximum temperature recorded in the chamber
will be visualised on the display.
Pushing the enter button the defrost led is reset to standard operation.
The display shows [rES] after the abnormal event.
.
.