Oase Aquarius Universal Classic 440 Instrucciones De Uso página 185

Ocultar thumbs Ver también para Aquarius Universal Classic 440:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 512
Storage/winter protection
Shut down the unit at water temperatures below +4 °C or at the latest when freezing tempera-
tures are expected.
Malfunction remedy
Malfunction
Pump does not start
Pump does not transport fluid
Insufficient flow rate
Pump switches off after oper-
ating briefly
Cause
No mains voltage
Supply lines kinked
Supply lines blocked.
Impeller unit is blocked
Flow rate is set too low on the
controller
Filter housing clogged
Excessive loss in the supply
lines
Impeller unit is running slug-
gishly
Water heavily soiled
Impeller unit is blocked
Pump has run dry
Water temperature too high
Remedy
Check the mains voltage.
Route the supply lines without kinks
Check/clean the supply lines
Remove blockage, check impeller unit for
ease of movement
Increase flow rate on the controller
Clean strainer casings
Reduce hose length to the necessary mini-
mum, remove unnecessary connection
parts
Check impeller unit for ease of movement
Clean pump
Remove blockage, check impeller unit for
ease of movement
Check/clean the supply lines
Adhere to the maximum permissible water
temperature. (→ Technical data)
EN
25
loading

Este manual también es adecuado para:

Aquarius universal classic 440i