Commissioning - Power supply units:
Device starts automatically once it is connected to the power supply After 1
second, you will hear a rhythmic even ticking of the pulses; the device is in
operation.
The energizer transmits pulses to the fence and the LED display lights up.
The fact of the status LEDs not lighting up points to a defect in the power
supply
Checking the earthing (10958):
Provoke a short-circuit by driving a metal rod into the ground against the
pasture fence wire (not plastic) about 50 m away from the pasture fencer.
The pasture fencer should now result in the lighting up of only a maximum 1
LED (moist ground) or of a maximum 2 LEDs (dry ground) (Fig. 2 LED 9 and
8). If this is not the case, then raise the number and / or length of the earth-
ing posts.
4. Energizer Operating Description
Rechargeable battery indicator:
The rechargeable battery indicator (Fig. 2 LED 2) provides information about the rechargeable battery or
battery voltage. The solar display lights up constantly in green when the solar panel charging voltage is greater
than the voltage of the rechargeable battery/battery. Whilst the solar panel charges the 12V rechargeable
battery, it does not charge the 9 volt battery.
Power economiser:
A fi tted power economiser matches power consumption to the state of the fence. This means less current con-
sumption with well insulated fences and a greater current consumption with poorly insulated fences (leakages
due to plant growth, etc.).
5. Maintenance
Table 13 (12V rechargeable battery)
Flashing light green
Flashing light red/green
Flashing light red
The rechargeable battery must be recharged at the latest when discharged down to 20% (only 80% charge
capacity left) to prevent a fl at battery. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these fi gures to vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied -
cover panel )
Remaining capacity
20-40 %
0-20 %
Rechargeable battery good
40-100 %
Charge the battery
Rechargeable battery abso-
lutely depleted