StetSom EX 3000 Black Edition Manual De Usuario página 14

Idiomas disponibles

Idiomas disponibles

Indicators LED
Smart protection system
When the protection system detects a failure, the amplifier will turn off and the PROT
LED will blink. For each type of failure, the LED will flash a certain number of times
indicating the cause, as shown in the table below:
Diagnostic: Short circuit or output overload.
Solution: Check that the speaker cables are well insulated and that the output
blink
1x
impedance does not exceed that supported by the amplifier.
Diagnostic: Excessive temperature. When the amplifier reaches approximately 194°F,
audio is stopped and the coolers run at maximum speed to speed up the cooling process
of the internal components.
blink
Solution: Check if the amplifier is in a ventilated place or if the coolers are not
2x
obstructed. Keep the amplifier turned on for a few minutes for the coolers to assist in
the cooling process.
Diagnostic: Supply voltage less than 9V.
blink
Solution: Check voltage of battery or power supply.
3x
Diagnostic: Supply voltage greater than 16V.
blink
Solution: Check voltage of battery or power supply.
4x
POWER (blue LED):
on.
PROT (top red LED):
malfunctions and entered protection mode, forcing it to shut
down. Verify in the protection table below the possible
problem and turn on the amplifier again.
CLIP (lower red LED):
amplifier output.
Indicates amplifier operation when it is
Indicates that the amplifier encountered
Indicates signal distortion at the
14
loading