RCA cables
REM
Remote: 18 AWG
STETSOM
Player
Troubleshooting
AMPLIFIER DOES NOT TURN ON:
• Verify that the cables are connected correctly. Make sure all connections have electrical
and mechanical contact.
• Fuses or circuit breakers may be defective or blown. Check the condition of the circuit
breakers and if it is compatible with the equipment consumption.
• Verify that the battery charge is sufficient for the operation of the product.
NO SOUND:
• The cables of the speakers or RCA plugs may not be connected correctly or are defective.
• Verify that the LEVEL control is not at a minimum.
PROT LED FLASHING:
• Verify that the product vents are not blocked or the product is overheated.
• Speakers or cables shorted, check speakers, cables and connections.