6. Operation
6.1 On/Off switch (Fig. 1/2)
Switch position 0:
Off
Switch position I:
On
6.2 Dry vacuuming
Use the dirt bag (14) and the additional fi lter (18)
for dry vacuuming (see point 5.2).
Always ensure that the fi lters are perfectly secure.
6.3 Wet vacuuming
For wet-vacuuming, use the foam fi lter (15) (see
point 5.2).
Check that the fi lter is securely fi tted at all times.
When wet vacuuming, the fl oating safety switch
(Fig. 3/5) closes when the maximum tank level
is reached. In doing so, the suction noise of the
equipment will change and become louder.
You must then switch off the equipment and em-
pty the tank.
Danger!
The wet and dry vacuum cleaner is not suitable
for the vacuuming of combustible liquids.
For wet vacuuming, use only the supplied foam
fi lter.
6.4 Blowing
Connect the suction hose (10) to the blow con-
nector (9) on the wet and dry vacuum cleaner.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the battery before starting any
cleaning work.
7.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible.
•
We recommend that you clean the equipment
immediately after you use it.
7.2 Cleaning the appliance head (1/3)
Clean the appliance regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plas-
tic parts in the appliance.
Anl_TC_VC 1820 Li Kit_SPK9.indb 20
Anl_TC_VC 1820 Li Kit_SPK9.indb 20
GB
7.3 Cleaning the container (1/7)
The container can be cleaned with a damp cloth
and some soft soap or under running water, de-
pending on the amount of dirt.
7.4 Cleaning the fi lters
Cleaning the pleated fi lter (Fig. 2/18)
Clean the pleated fi lter (18) regularly by carefully
patting it and cleaning it with a fi ne brush or hand
brush.
Cleaning the foam fi lter (2/15)
Clean the foam fi lter (15) with a little soft soap un-
der running water and allow it to air-dry.
7.5 Servicing
At regular intervals and before each use, check
that the fi lters in the wet and dry vacuum cleaner
are securely fi tted.
7.6 Ordering spare parts
Please provide the following information on all
orders for spare parts:
•
Model/type of the equipment
•
Article number of the equipment
•
ID number of the equipment
•
Part number of the required spare part
For our latest prices and information please go to
www.isc-gmbh.info
8. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
9. Storage
Store the equipment and accessories in a dark
and dry place at above freezing temperature. The
ideal storage temperature is between 5 and 30
°C. Store the electric tool in its original packaging.
- 20 -
20.11.2017 14:19:52
20.11.2017 14:19:52