2.9.- STARTING THE APPLIANCE
a.- Open the gas passage of the general supply network.
b.- Connect the electric cable
1.- Ignition of the burners
-The lighting order is from top to bottom, NEVER TURN ON A BURNER
WITHOUT HAVING THE SUPERIOR BURNER ON, SINCE IT WOULD
BE VERY DIFFICULT TO TURN IT ON AND IT COULD BURN
- Open the glass door.
- Press and turn the knob to the position of maximum Large flame.
- Light the burner with a long lighter.
- Keep the knob depressed for 20 seconds, to allow time for the safety
valve to act
- Regulate the flame of the burner at the desired power
2.- Starting the engine
Press the switch and place it in position (1) the engine will turn on and
the switch will light
3.- Turning off the burners
To turn off the appliance, simply turn the knob to the off position (0).
It is recommended to close the gas passage of the general supply ne-
twork.
4.- Engine shutdown
Press the switch and place it in position (0) the switch will turn off.
2.10.- CHECKING THE FUNCTIONING OF THE DEVICE
Once turned on, a check of the operation will be carried out always fo-
llowing the indications of the country of destination for the installer. It is
the responsibility of the installer to carry out these checks according to
the regulations in force.
Paying special attention to:
1.- Connection nozzle
2.- Sealing
3. Appearance of the flames and Power
4.- Minimum position
5.- Security devices
16