Replacement of the peristaltic pipe
5.1 Replacement of the peristaltic pipe
Roller holder
in vertical
position
Screw 1
Rinse with clean water the pump body, the valve, the peristaltic pipe and the injector.
Place the roller holder on a vertical position.
Remove and identify clearly the suction and discharge pipes.
Unscrew the 2 screws in order to remove the cover of the pump body.
Slowly unclip the suction union, then swivel the pipe around the upper roller
Then unclip the union on the discharge side, the pipe and unions are now completely removed.
Replace the new pipe the same way, beware not to pinch it.
Replace the cover and tighten the screws again.
5.2 Cleaning of the probe
Dip the probe in an acid solution (such as vinegar). Wait 5 minutes and rinse the probe with clean water.
Do not leave the probe in the open air. Put the original cap filled with water back on it, so that the head always
remains wet.
5.3 Storage after use
The pipe must be rinsed with clean water, dismantled and stored in a temperate place.
6.0 FREQUENTLY ASKED QUESTIONS
Fact
No display
Wrong value displayed
Wrong value displayed
after re-calibration
Calibration impossible
Gap between the read
value and the set point
No injection
No rotation
!!! Please neither intervene nor send the pump back to our After-Sales Department without making it
work with water beforehand, in order to clean the pump body !!!
100897- indB – 0209
Screw 2
Causes
Electric supply
Broken fuse
Broken electronic regulator
Wrong calibration of the pump
Electronic regulator out of order
Probe out of order
Broken electronic regulator
Probe out of order
Used buffer solution
Bad position of the probe
Wrong calibration of the pump
Level of chemical solution too low
Drained dosing pump
Valves blocked or broken
Worn peristaltic pipe
Worn roller
Micro-motor broken
Electronic regulator out of order
23 / 40
Once a year
Remedies
Check supply voltage and interlock to the
filtration pump
Replace the fuse
Contact your retailer
Re-calibrate the probe
Contact your retailer
Replace the probe (wear and tear part)
Contact your retailer
Replace the probe (wear and tear part)
Change the buffer solution
Check the installation
Re-calibrate the pump
Fill the chemical solution tank
Prime the pump
Rince with water
and if necessary change the
valves
Change the pipe
Replace the roller and the roller holder
Contact your retailer
Contact your retailer