Install the pump horizontally using a spirit level. Position the drilling holes for wall mounting, using the drilling
template. Tolerance is + / - 15° for the vertical.
Install the female wall mounting parts using the installation set that is provided.
.
Position the boards
3.2 HYDRAULIC CONNECTION
It must be made (probe, injection) on clean and filtered water, at the filter outlet, on the return pipe and
specifically on a straight part where the water flow may not be hampered.
Install the mounting claps that are provided (probe and injection) on the pipe at 0.5 m minimum from one
another. (Probe upstream and injection downstream the return pipe). Seal with a patch, a cap or a second-hand
probe if water is running in the pipe. In any case, do not install the probe unless water is perfectly filtered.
Example of installation of a pH pump with a salt chlorinator and a pool heater
Example of installation of a pH and Rx pumps with a pool heater
3.2.1 SOLUTION TO BE INJECTED
The peristaltic pipe and the other elements making the hydraulic part are designed to inject sulphuric acid, sodium
hypochlorite or sodium hydroxic (soda).
In the case of use of hydroxide of sodium (soda pH +), use pH + kit (extra, not included)
The use of any other chemical product (such as hydrochloric acid) is forbidden as they may damage the pump.
No warranty will be awarded for a pump containing other chemical products.
It is compulsory to identify clearly the chemical solution tanks with indelible marking.
3.3 SUCTION
A 2m flexible pipe is supplied with the pump, designed for suction. Cut it at the adequate length, depending on
the pump room layout.
Connect the flexible suction pipe to the valve.
100897- indB – 0209
17 / 40
1 : Suction valve
2 : Discharge valve
3 : Pipes setting
4 : Fastening of cable glands