4.1.7 ENTERING THE POOL VOLUME
In order to optimize the regulation, the pool volume that has to be treated must be entered.
Keep pushing the DOWN button
Push the ENTER button
volume of the pool
Push the ENTER button
Enter the volume of your pool using the UP and DOWN buttons
Push the OK button
Maximum volume for MIXY Link pH : 440m
Maximum volume for MIXY Link Rx : 220m
4.1.8 OPTIONS
Keep pushing the DOWN button
Push the ENTER button
OPTION followed by the name of the Option.
Using the UP and DOWN buttons, activate (ON) or cancel (OFF) the adequate option.
Push the OK button to validate
Definition of options
SECURITY
When activated (ON), this option provides an additional security that stops the dosing pump in case of
problem on the chemical product injection circuit (defective pump motor, defective pipe, etc).
No cable connection is to be made.
As a default setting, this option is not activated (OFF).
In case of defect, the message Alarm Security will appear on the second line of the display screen.
LOW LEVEL ON CHEMICAL SOLUTION TANK
When activated (ON), this option brings an additional safety that will stop the working of the dosing
pump in case of low level in the chemical solution tank.
In order to use this function, activate the Option and install a level regulator ref. PDRNF in the
bottom of the chemical solution tank. Cable the 2 wires of the level regulator (not provided) on the
connector (marked as 'Tank' on the electronic card). You'll have to drill and use a cable gland (not
provided) in order to pass the cable.
In case of defect, the message LOW LEVEL TANK will appear on the second line of the display screen.
FILTRATION AUTO START
When activated (ON), this option will start the filtration automatically. When the pump is not running,
Mixy Link will start it every 3 hours during 300 seconds, in order to check that the level of pH or Rx is
OK. If not, it will make the filtration run until the set point is reached.
As a default setting, this option is not activated (OFF).
In order to use this function, connect a cable 2 x 0,75mm² H03VVF between the connector (marked as
'comF' on the electronic card) and the contact NO (shut in this case) of the timer that controls the
filtration pump (usually terminals 3 and 4). You'll have to drill and use a cable gland (not provided) in
order to pass the cable.
The filtration pump must be switched on the AUTO position.
In case of defect, the message Alarm Auto start will appear on the second line of the display screen.
FLOW SWITCH
When activated (ON), this option ensures an additional protection by controlling the water flow in the
pipe upon which the injection is placed.
100897- indB – 0209
until you reach the menu PARAMETERS
then keep pushing the DOWN button
the message Pool volume will be displayed
to validate or CANCEL © to exit the programming step without saving.
3
until you reach the menu PARAMETERS
then keep pushing the DOWN button
or CANCEL © to exit the programming step without saving
21 / 40