3.5.1 Sendix 58xxFSx
Mechanical characteristics for the Sendix 58xxFS
encoders
Maximum rotational speed **
Maximum angular acceleration
Ambient temperature **
Protection level according to EN
60529
Pollution degree according to EN
61010
Installation height
Weight
Shock resistance according to EN
60068-2-27
Vibration resistance according to
EN 60068-2-6
** Limitations, see chapter Limitations [} 57].
42 - EN
-1
12000 min
5
5x10
rad/s²
-40°C ... +90°C
[-40°F ... +194°F]
IP65 / IP67
2
< 2000 m [6562 ft]
appr. 0.45 kg [15.87 oz]
2
1000 m/s
, 6 ms
8.7 ... 200 Hz, 30 m/s²
200 ... 2000 Hz, 200 m/
s²
Electrical data for the Sendix 58xxFS encoders
Supply voltage
Supply voltage according to UL
1310
Current consumption (no load)
5 V DC
10 ... 30 V DC
Protection class according to EN
61140
Smallest safe measuring step
General technical data of the SinCos interface
Max. frequency -3dB
Short-circuit resistance
Number of pulses
Offset
Offset difference between A
and B
Amplitude
Amplitude difference
between A and B
Phase position A vs. B
Terminating resistor
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 03
5 V DC, ± 10 %
10 ... 30 V DC
Class 2
max. 80 mA
max. 50 mA
III (PELV)
10 % of a SinCos period
400 kHz
Yes
1024 / 2048 ppr
2.5 V (± 100 mV)
max. 25 mV
1 V
(± 10%)
pp
max. 40 mV
90° (± 10%)
120 Ω