5. The lamp can now be removed from the holder.
6. Loosen and remove the two screws on the contacts of the lamp.
7. When inserting the new bulb, follow these steps in reverse order and ensure that all screws are tight. Never operate the spotlight without
lamp cover and head cover .

CALIBRATING THE LAMP

Important:
Calibration of the lamp may be carried out by qualified personnel only. If you do not have these qualifications, do not attempt to
calibrate a lamp.yourself. Refer instead to a qualified professional.
A hot discharge lamp is under high pressure and can therefore spontaneously explode. Let the lamp cool for at least 30
minutes before opening it.
When calibrating the light, use protective glasses and protective gloves and do not operate the spotlight without the lamp cover
and head cover.
If the hotspot is not in the centre of the projection of the light beam, it can be calibrated on the horizontal plane.