13. Troubleshooting
Supposed malfunctions, errors or damages are often caused by events which can be remedied by the operator.
Therefore check the power tool on the basis of the following table before you contact a specialist. Many malfunc-
tions may thus be remedied.
Problem
Power tool does not
start
Power tool does not
operate with full power
Poor operation results
Considerable dust
formation
30 | GB
Possible cause
Power supply interrupted
Power cord or plug defective
Other electrical defect of the power tool
Extension cord too long and/or cross-
section too small
Power supply (e.g. generator) voltage
too low
Power tool worn out
Grinding plate worn out
Brush edge worn out
Dust extraction not connected / switched
on
www.scheppach.com
Approach
Check power supply by connecting
another power tool
Have an electrician check the tool
Have an electrician check the tool
Use extension cord with permissible
length and/or adequate cross-section
Connect power tool to an appropriate
power supply
Replace insertion tool
Have grinding plate replaced
Have brush edge replaced
Connect / switch dust extraction