CONTROL PANEL
3
2
1
5
 1 General switch
 2 Display
 3 Water-filling cap
 4 Steam adjustment knob
 5 Connector block for hose
PREPARATION and START TO USE
Open the cap (3) and fill the tank with tap water.
-Note: If the water available should be
"very hard"(>20°F), It is recommended the use of 50%
demineralized water or distilled water, (this to avoid
excessive limestone formations and to be sufficiently
conductive)
ATTENTION: Do not add detergents, anti-limestone
solutions or essential oils in the water tank boiler, these
can cause irreparable damage to the boiler and circuits.
The manufacturer is not responsible for any damage
caused by improper use.
Connect the plug to a socket on an electrical
interconnection conformed to the rules of the country,
equipped with a switch and an earth terminal efficient.
START TO USE:
Turn the main switch on (1).
The display (2) will turn on and indicate the
temperature-pressure status of the machine, when the
machine is ready, it will visualize "170". (usually the
machine needs around 2÷3 minutes to be ready.)
The machine starts heating.
Choose the most suitable accessory for the needed
use and connected it to the multifunction handle, by
means of the extension tubes, then insert the hose
connector as shown by the white arrow in the picture.
4
When the machine is ready, to release steam through
the handle of the flexible, press the lever button (6).
Now use the brush or accessory in the surfaces to be
cleaned.
Attention: it is recommended to perform the first
release of steam after the heating on a container for
about a minute, this is to collect any condensate water
generated in the initially cold ducts.
Attention: if you are working on delicate
surfaces or things, keep the steam jet at an
adequate distance of at least 20-40cm.
STEAM RELEASE REGULATION:
Through the regulation knob (4) placed
frontally on the machine, you can gradually adjust the
release of the steam.
END OF WATER: The acoustic and the visual
indicator of the display (2), indicates when there is no
more water inside the tank by showing "H2O", this is
why the machine will stop the steam release.
WATER SUPPLY:
Proceed as decribed:
Open the cap (3) and refill the tank with water (see
note PREPARATION).
Close the cap.
Push the lever button (6) of the hose handle to re-start
working. (you can hear the pump starting to work)
please wait a few seconds and then re-start your