Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the FY-200 starts running. During the Reset, the motors are
trimmed and the device is ready for use afterwards.
Remove the focus cover and turn the focus screws for adjusting the focus in order to obtain a sharp
projection.
Stand Alone operation
In the Stand Alone mode, the FY-200 can be used without controller. You can do without a controller as the
FY-200 features a built-in microphone, which provides automatic sound control.
Disconnect the FY-200 from the controller and select "Master Mode: Sound-control".
If you have connected a footswitch to the Blackout-socket, you can lock the light output (Blackout-mode) and
turn it on again.
Master/Slave-operation
Connect the master and slave-devices and adjust the settings as desribed above.
Please note: If you wish to change from one operating mode into another, you have to unplug the projector
from the mains and plug it again.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. In order to call up the different features, you first have to open the light
output (control channel 6, DMX-value 250-255).
Addressing
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the FY-200 will respond to the controller.
Please, be sure that you don't have any overlapping channels in order to control each FY-200 correctly and
independently from any other fixture on the DMX data link.
If two, three or more FY-200 are addressed similarly, they will work similarly.
For address setting, press the Mode-button until the display shows "d" and set the desired address via the
Up/Down-buttons.
International
L
N
29/63
51837535_V_1_0.DOC