Automatic switches
6. OPERATION
(cont.)
Override light-on mode
- Override in inductive mode (Cat. No. 670 91)
- Override in capacitive mode (Cat. No. 670 91)
- Return to automatic mode (Cat. No. 670 91)
Technical data sheet: F00548EN/03
CONTENTS
ON
for 10 seconds
for 10 seconds
for 10 seconds
Updated: 17/07/2009
Cat. No(s): 670 91/92
7. TECHNICAL DATA
7.1 Technical characteristics
Impact resistance: IK 04
Penetration by solid/liquid bodies: IP 41 (C15-100)
7.2 Material characteristics
Cover: Polycarbonate
Base: Polycarbonate
7.3 Electrical characteristics
Self-extinguishing: 650 °C / 30 s
Voltage: 110-230 V
Frequency: 50-60 Hz
Power: Cat. No. 670 91
Max.
400 W
240 V~
Mln.
40 W
Max.
200 W
100 V~
Min.
40 W
Power: Cat. No. 670 92
240 V~
1000 W
1000 W
500 VA
100 V~
500 W
500 W
250 VA
1 - Incandescent lamp
2 - Halogen lamp
3 - ELV halogen lamp with ferromagnetic or electronic transformer
4 - Fluorescent tube
5 - Compact fluorescent lamp
6 - Compact fluorescent lamp with separate transformer
7 - Fan motor
8 - Contactor
9 - ELV halogen lamp with ferromagnetic transformer
10 - ELV halogen lamp with electronic transformer
7.4 Climatic characteristics
Storage and operating temperature: 0 °C to +35 °C
8. CLEANING
No cleaning.
Created: 24/10/2007
+
+
+
+
400 W
400 VA
400 VA
40 W
40 VA
40 VA
200 W
200 VA
200 VA
40 W
40 VA
40 VA
500 VA
500 VA
500 VA
100 VA
250 VA
250 VA
250 VA
50 VA
+
+
+
+
I max
< 2 A
I max
< 1 A
3/3