Automatic switches
5. CONNECTION
(cont.)
Cat. No. 670 91 (without neutral)
N
L
L
≠
Only possible with incandescent loads and electronic transformers.
Respect minimum load: 40W multiplied by number of inputs
Respect maximum load: 400 W
5.3 Assembly with remote push-button (NC)
N
L
n
6. OPERATION
6.1 General operation
- Detection angle in horizontal plane: 180°.
- Possibility of remote manual control with an NC push-button.
- ON/OFF functions.
- For Cat. No. 670 91 built-in self-protection against overloads and
short-circuits.
- Installation in a min. 40 mm deep flush-mounting box.
Time delay adjustable
from 1 sec to 16 min,
cycle repeated as long as
device detects movement.
6.2 Detection levels
Horizontal detection
Range set to 3 m
Technical data sheet: F00548EN/03
CONTENTS
L
L
≠
≠
400 W max
L
N
≠
Detection range adjustable
from 3 to 10 m
Brightness threshold
adjustable from 3 to 1000 lux
Updated: 17/07/2009
Cat. No(s): 670 91/92
6. OPERATION
(cont.)
Range set to 10 m
Vertical detection
Range set to 3 m
1.2 m
1.2 m
1.5 m
1.5 m
Range set to 10 m
1.2 m
1.2 m
5 m
5 m
6.3 Precautions for use
6.4 Usage modes
Automatic mode: after pressing on central "Auto" button
(auto marking on mechanism)
Created: 24/10/2007
5 m
10 m
3 m
3 m
10 m
10 m