Wiring
See Figure 3.
Connecting cable:
•
1 to 4: tinned copper
•
5 (Red): +
•
6 (Blue): −
Before connecting, the wires must be electrically checked. The
opposite wires are always connected, you can check the
resistance 0 Ω between them. For multiple detector
connection, you can use two adjacent wires as an input, and
the other two as an output, disregarding the direction. See
Figure 4 for an example.
Testing
The function of the glass break detector can be tested after the
installation with the test set GS331.
Optional accessories
•
GS303: Glass break detector adhesive set with cleaning
towels
•
GS331: Glass break detector tester
Specifications
Mounting
Surface
Indication
LED
Housing bottom
Ceramic substrate
Voltage
9 to 18 V
Voltage ripple, p-p
1,0 V max.
Current consumption
about 0,6 mA / about 5 mA
(standby/triggered)
Switching current
200 mA max.
Switching power
0,3 W max.
Reset voltage
2,2 V max.
Reset time
10 ms min.
about 5 Ω
Contact resistance
Contact capacity
about 10 nF
Floating limit
50 V
LIYY 6X 0,14 mm² tinned copper
Connecting cable
4X black, 1X red (+), 1X blue (−)
Inner conductor
Ø3,8 mm (<10 m authorized by VdS)
Cable dimensions
GS320
2 m
GS321
6 m
GS322
20 m
Housing dimension
37 x 19 x 12 mm
Housing material
S-B
Colour
White
−40 to +70°C
Operating temperature
Flat glass (6 mm), security glass (ESG)
Glass types
(6 mm), insulating glass (4 mm)
Glass size per detector
40 x 40 cm min., 200 x 100 cm max.
Protection category
VdS environmental class III A
IP rating
IP 67
2 / 10
Regulatory information
Manufactured for
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
European Union
Carrier Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.firesecurityproducts.com or
www.aritech.com.
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Contact information
www.firesecurityproducts.com or www.aritech.com
For customer support, see www.firesecurityproducts.com
DE: Installationsanleitung
Beschreibung
Der Glasbruchsensor überwacht ebene Glasflächen innerhalb
eines Radius von max. 2 m. Der Überwachungsradius ist
abhängig von der Glasscheibenstärke, den
Alterungszuständen der Glasscheibe, der
Glasscheibenrahmung (Metall, Kunststoff, Holz) und der
Glasscheibenkittung (Glaskitt, Silikon).
Glasbrüche, deren mechanische Schwingungen den
Glasbruchsensor nicht in der entsprechenden Frequenz und
P/N 1078283 (ML) • REV E • ISS 09DEC20