ZAF
Trouble Shooting:
1.
Blower does not reach operating speed when starting:
1.1 Check that the incoming voltage and frequency corresponds with the motor data plate.
1.2 Check the connections on the motor terminal block.
2.
Motor starter cuts out blower:
2.1 Problem as per 1.1 and 1.2.
2.2 Incorrect setting on the motor starter.
2.3 Motor starter trips too fast.
Solution: Use a motor starter with a time delay trip (version as per IEC 947-4).
2.4 Blower is overloaded, i.e. pressure difference is too high.
Solution: Increase the inlet or outlet diameter of the application, on pipework increase the diameter of the pipework, avoid restrictions in the
line. Limit the pressure difference by limitation valves (optional extra).
2.5 Motor rating selected was too small.
Solution: If available use a blower with the next motor size (exchange of the motor only is not possible).
3.
Required pressure difference cannot be achieved:
3.1 Blower or motor rating selected was too small.
3.2 Filters are contaminated.
3.3 Pressure loss into pipework too high.
Solution: Use bigger pipe diameter, avoid restrictions.
3.4 Leaks on the system.
4.
Blower operates at an abnormally high temperature:
4.1 Ambient or suction temperature is too hot.
4.2 Pressure difference is higher than permitted.
4.3 Cooling air flow is restricted.
5.
Exhaust noise at (B
) and / or suction noise at (A
1
Solution: Use an additional silencer ZGD (optional extra).
Appendix:
Repair on Site: For all repairs on site an electrician must disconnect the motor so that an accidental start of the unit cannot happen.
All engineers are recommended to consult the original manufacturer or one of the subsidiaries, agents or service agents. The address of the nearest
repair workshop can be obtained from the manufacturer on application.
After a repair or before re-installation follow the instructions as shown under the headings "Installation and Initial Operation".
Lifting and Transport: To lift and transport units SKK above size 302 02 the eye bolt on the unit must be used.
The weight of the blowers is shown in the accompanying table.
Storage: SKK units must be stored in dry ambient conditions with normal humidity. We recommend for a relative humidity of over 80% that the
pump units should be stored in a closed container with the appropriate drying agents.
Disposal: The wearing parts (as listed in the spare parts lists) should be disposed of with due regard to health and safety regulations.
Spare parts lists:
E 513
E 516
SKK
Noise level (max.) /
dB(A)
Sound power*
Weight (max.)
Length (max.)
Width
Height
f
h
1
) are unacceptable:
1
SKK 253 02 - SKK 382 02
SKK 334 03 - SKK 382 03
253 02
50 Hz
72
60 Hz
74
kg
25
mm
396
mm
314
mm
311
m
f
1
2
µ
m
302 02
334 02
74
76
76
78
45
42
487
420
364
380
376
398
2
382 02
334 03
80
78
82
80
58
45
464
488
414
382
447
400
ZVF
382 03
82
84
63
530
414
447
1.2001
/ PM6