MACHINE TROUBLESHOOTING
Problem
Bulbs do not come on
Sticky or tacky floor after curing
y
y
Surface looks rough after curing
Visible overlap stripe
SPECIFICATIONS
Item
Width
Height
Length
Bulbs
Volts
Amps
Cord length (machine)
Extension Cord maximum length (option)
Curing speed / walking pace
GVWR
SunFlash 331130 (9- -04)
Cause
Machine not plugged in
Machine recently unplugged
Bulbs burned out
Outlet CB tripped / fuse blown
Machine CB tripped
Defective cord
g
Curing speed too fast
Lights not on
Coating not relaxed enough
Side shields too high
Dimension/capacity
692 mm (27.25 in)
953 mm (37.5 in)
1143 mm (45 in)
400 watt each / 1200 watt total with 3 bulbs
110V
12
152 mm (6 in) 14 / 3 gauge
30.5 M (100 ft) 14 / 3 gauge
305 mm (12 in) every 4 seconds
25 kg (55 lb)
OPERATION
Remedy
Plug machine in
Allow the bulbs / machine 5 min-
utes to cool down
Replace bulb
Reset CB or replace fuse
Reset machine CB
Replace cord
Push machine at a slower pace
See "Bulbs do not come on"
above
Allow longer time for coating to
relax before curing with machine
Lower side shields