Rejection rate is too low: Check the water flow rates (waste water, pure water). If the water
flow is ok, flush the unit for approx. 60 min. If the rejection rate increases, go on flushing until
the value is acceptable. If the rate does not improve, change membrane.
6. Important Notes
-
Connection: Connect the reverse osmosis unit to cold water supply only. Higher temperatures
increase pure water production but at temperatures more than 40 °C, the membrane will be
destroyed.
-
Stopping the unit: If you stop the unit, always close tap water supply. Never only close the
pure water tap. If you run the unit automatically with a solenoid valve, switch the valve
between pre-filter and module. Take care that waste water and pure water can flow away freely.
-
Disconnection of the unit: If you want to disconnect the unit for a longer period than 6
weeks, you should add Aqua Medic disinfection liquid into the module housing. If the unit is
started again, flush it for 15 to 20 minutes. We recommend flushing also after shorter periods of
stopping, if no disinfection liquid has been used.
-
Storage: The unit has to be stored at temperatures above 0° C. Freezing would destroy the
membrane.
8. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid.
Proof of Purchase is required by presentation of the original invoice or receipt indicating the
dealer's name, the model number and date of purchase. This warranty may not apply if any model
or production number has been altered, deleted or removed, unauthorised persons or organisations
have executed repairs, modifications or alterations, or damage is caused by accident, misuse or
neglect. Please note that the product is not defective under the terms of this Warranty where the
product, or any of its component parts, was not originally designed and / or manufactured for the
market in which it is used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany