Hilti SID 4R-22 Manual De Instrucciones Original página 14

Ocultar thumbs Ver también para SID 4R-22:
Idiomas disponibles

Idiomas disponibles

Status
One (1) LED quick-flashes yellow
One (1) LED shows yellow
One (1) LED quick-flashes red
3.4.2 Indicators showing the battery's state of health
To check the battery's state of health, press the release button and hold it
down for longer than three seconds. The system does not detect a potential
malfunction of the battery due to misuse, for example battery dropped or
pierced, external heat damage, etc.
Status
All LEDs show in sequence, fol-
lowed by one (1) LED showing con-
stantly green.
All LEDs show in sequence, fol-
lowed by one (1) LED quick-flashing
yellow.
All LEDs show in sequence, fol-
lowed by one (1) LED showing con-
stantly red.
10
English
Meaning
The Li-ion battery or the product in
which it is inserted is overloaded,
too hot or too cold, or experiencing
some other fault.
Bring the product and the battery
to the recommended working tem-
perature and do not overload the
product when it is in use.
If the message persists, consult
Hilti Service.
The Li-ion battery and the product
in which it is inserted are not com-
patible. Consult Hilti Service.
The Li-ion battery is locked and
cannot be used. Consult Hilti Ser-
vice.
Meaning
The battery can remain in use.
The check to ascertain the battery's
state of health did not complete.
Repeat the procedure, or consult
Hilti Service.
If a connected product can still be
used, the remaining battery capac-
ity is below 50 %.
If a connected product can no
longer be used, the battery has
reached the end of its useful life
and has to be replaced. Consult
Hilti Service.
2373959
*2373959*
loading