voestalpine bohler welding URANOS 1800 TLH Manual Del Usuario página 29

Ocultar thumbs Ver también para bohler welding URANOS 1800 TLH:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
3.2.2 Alarm codes
E01, E03
Temperature alarm
E11
System configuration alarm
E20
Memory fault alarm
E21
Data loss alarm
E42
Undervoltage alarm (115V)
3.3 Rear panel
1
Power supply cable
Connects the system to the mains.
2
Gas fitting
3
Signal cable (CAN-BUS) input
4
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
3.4 Sockets panel
1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.
3
Gas fitting
4
Torch button connection
4 ACCESSORIES
4.1 General
Operation of the remote control is activated when connected
to the power sources. This connection can be made also with
the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 100 remote control
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".
4.3 RC 120 pedal remote control
Once the power source has been switched to the EXTERNAL
CONTROL mode, the output current is controlled from a
minimum to a maximum value (can be entered from SETUP) by
varying the foot pressure on the pedal surface. A microswitch
provides the start trigger signal at minimum pressure.
"Consult the instruction manual".
4.4 RC 180 remote control
This remote control unit makes it possible to change the output
current without interrupting the welding process.
"Consult the instruction manual".
29
loading