TECHNICAL MANUAL. START-UP AND OPERATION
B. Installation conditions
Do not install the unit near a flammable gas source, since a gas leak may occur and cause an explosion.
SPECIFIC INSTRUCTIONS: It is obligatory for users contact a specialized company that has experience installing and repairing
heat pumps. Users should not install or repair the heat pump themselves nor should another person do it.
The operating environment of the unit usually varies between 10 ºC and 35 ºC.
4. DESCRIPTION OF THE HEAT PUMP
A. Technical characteristics
- The calculation of power has been done with an outdoor air temperature
27
of
ºC, a water temperature of 0 ºC and 70% humidity.
- Operational temperature limits:
· Outdoor minimum air temperature: 5ºC
· Maximum temperature of pool water: 36ºC
- Maximum inlet water pressure 3,5 bar.