PROHEAT II SERIES · HEAT PUMP AIR/WATER SYSTEM
The arrangement of the air ducts must be of an adequate size and the loss of load of the
ducts must not exceed the available pressure of the installed fans.
The aspiration and impulsion of the equipment will be installed at a sufficient distance
between them so that undesired recirculation can not occur.
It is also desirable to provide a removable door or plate in the outdoor air intake duct to
be able to check its condition and proceed to clean any dirt that may be trapped in the
air inlet of the unit.
Leave at least 1 meter of unused space around the equipment to facilitate personnel
access and maintenance operations.
The primary hydraulic circuit, used to heat the pool water, must not be galvanized steel
or aluminum. Corrosion problems may appear due to galvanic corrosion
The standard and chiller models have been designed for outdoor installation
(never indoors).
The Indoor models have been designed for installation indoors (never
outdoors).).
THE WARRANTY WILL BE VOID IF THIS CONDITION IS NOT FULFILLED
5.3.

OPERATING CONDITIONS

Water physical and chemical parameters must be in between:
PH ......................................................... 7,2 a 7,8
Residual chlorine ................................... 1 a 2 ppm
Alkalinity ............................................... 80-125 ppm
Total dissolved solids ............................ <=3000 mg/l
Hardness ............................................... 200-300 ppm
The limits established for working conditions in order to guarantee the proper operation of the
equipment are:
Minimum outside temperature: ........................... 0 °C.
Maximum pool water temperature: ..................... 40 °C.
Minimum water cooling temperature .................. 20º C (Only CHILLER MODELS, for
lower operating temperatures, consult Fluidra Comercial)
Maximum input water pressure:........................... 3,5 bar.
Maximum conditions of the technical room ......... 35 °C / 90% RH (INDOOR MODELS).
The operating conditions will affect the output of the equipment.
The operating conditions will influence the performance of the equipment and the power data
provided in the data sheet may vary, if these placement recommendations do not occur. It is