Installation (Continued)
Air Line Piping
Connection to air system
E
should be of the same size, or
N
larger, than discharge pipe out
G
L
I
S
CFM
H
20
40
60
100
plastic pipe or improperly
rated metal pipe. Improper
piping materials can burst
and cause injury or property
damage.

Operation

This compressor has been
inspected, thoroughly tested
and approved at the factory.
For this unit to give long
satisfactory service it must be
installed and operated properly.
This compressor has been designed
for a 80%/ ON – 20%/ OFF duty
cycle.
Simplex units have a pressure
switch that senses changes in
receiver pressure and
automatically starts and stops
the compressor at preset
pressure limits.
Duplex units have pressure
switches and an automatic
alternating system to evenly
distribute the load between
the two compressors. If the
receiver pressure drops below
135 PSI, both compressors run
until receiver pressure reaches
175 PSI. If the pressure in the
receiver drops below 145 PSI,
For Service and Warranty, Call: 1-888-303-1344.
4XA59 thru 4XA62, 4XA67, 4XA68, 1WD46, 1WD48, 1WD54, 1WD55,
1WD57, 1WD58, 1WD61, 1WD63 thru 1WD65, 13G706 thru 13G709
5 & 7.5 HP
®
of unit. The table below gives
recommended minimum pipe
sizes. A union connection to
the unit and water drop leg is
recommended. Install a flexible
connector between the discharge
of the unit and the plant air piping.
Minimum Pipe Sizes For Compressor Air Lines
(Based on Clean Smooth Schedule 40 Pipe)
25'
50'
3/4"
3/4"
3/4"
1"
1"
1"
1"
1 ¼"
but remains above 135 PSI, only
Never use
one compressor will run. The next
time the pressure in the receiver
drops, the system will automatically
start the compressor that was idle.
Initial Start Up
1. Pull main disconnect switch
to unit to assure that no
power is coming into the
unit. "Lock Out" or
"Tag Out" switch.
Connect power leads
to starter.
attempt to operate
compressor on voltage
other than that specified
on order or on motor.
2. Check compressor oil level.
Add oil as required. See
"Compressor Oil
Specifications" Section.
NOTE: Do not mix oil
type, weights or brands.
3. Inspect unit for any visible
signs of damage that would
have occurred in shipment
or during installation.
Plant air piping should be
periodically inspected for leaks using
a soap and water solution for
detection on all pipe joints. Air leaks
waste energy and are expensive.
100'
200'
3/4"
1"
1"
1"
1 ¼"
1 ¼"
1 ¼"
1 ½"
4. Activate main disconnect
switch.
5. "Jog" motor and check for
proper rotation by direction
arrow. If rotation is wrong,
reverse input connections on
the magnetic starter.
6. Close receiver outlet hand valve
and start.
7. With receiver hand valve closed,
let machine pump up to
operating pressure. At this stage
the automatic controls will
take over. Check for proper
cycling operation.
Do not
8. Check for proper operation
of any options. Refer to
individual option
instruction sheet.
9. When the initial run period
has shown no operating
problems, shut unit down and
recheck oil level.
10. Open receiver hand valve. The
air compressor unit is now
ready for use.
start automatically without