4.2.4.2- Control
The equipment allows you to select from 4 different modes of control:
Manual: The equipment produces chlorine continuously, depending on the
% of production selected. If you have a fitted ADVANCED probe Kit probe, it
will ignore its value and chlorination will not stop even though the set value has
been exceeded. When selecting this mode, the equipment will ask if you want
to display the value of the Redox probe (ORP) on the main screen.
Select this mode if you do not have an ADVANCED (Redox) probe Kit,
by adjusting production and hours of filtering depending on the nature of your
swimming pool, its volume number of bathers and season of the year.
Automatic
Select this mode only if you have an ADVANCED probe Kit (Redox) or
PRO/2 amperometric kit. If you do not have a probe, the equipment will act
at random and end up by stopping and showing an error.
This mode enables you to automatically adjust the level of chlorine in your
swimming pool. Based on the adjusted set value in the "chlorine" menu, the
equipment will stop when it reaches this value, and start-up again automatically
when there is a need for chlorine.
Semi-automatic
Select this mode only if you have a Temperature (NTC/1) probe kit. If
you do not have one, the equipment will not operate correctly in the semi-
automatic mode.
This work mode enables you to determine the daily hours of operation of the
salt water chlorinator based on the volume in m3 of the pool and the water
temperature. Once they have been reached, the chlorinator will stop although
the filtering pump will continue to operate.
Bear in mind that the equipment makes an approximate calculation of chlorine
which it has to produce, based on two known parameters. However, other
factors are not considered, such as the consumption of chlorine caused by the
number of bathers per day.
4.2.4.3- Cleaning
The equipment includes an automatic cleaning system, based on reversing
polarity in the electrolysis cell. These cleaning cycles are performed regularly.