3.3.2- EVO series equipment (EVoBASIC, EVoLOWSALT, EVoMg)
Earth connection
L, N:
Supply 220v
SW:
On / Off Switch
PH
pH pump connection (For units with the AUTO kit)
AUX R:
Auxiliary relay
FILTER:
Filter connection for Stop / Start mode
J4:
Terminal block of cell
J8:
1- (yellow) Acid sensor (PH)
2- (yellow) Acid sensor (PH)
3- (purple) Cover
4- (purple) Cover
5- (white) Water sensor (cell's white cable)
6- (white) External flow switch (5-6)*
7- (blue) Temperature probe
* activate the FLOW SWITCH operation in the configuration menu
** to connect the free chlorine probe, read 3.2.5 chapter
K1: PH Relay
K4: Auxiliary relay
LK2: Stop/Start (see 3.3.3.1)
F1: Fuse
Manual EVO v.4
8- (blue) Temperature probe
9- (brown) ORP-
10- (orange) ORP+ (**)
11- (red) 12V free chlorine probe
12- (gray) Conductiviy probe GND
13- (green) Conductivity (signal)
14- (red) Conductivity (12v)