Tectro R233TC-2 Instrucciones De Uso página 80

Ocultar thumbs Ver también para R233TC-2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
F
E
F
G
G
H
B
I
J
4
80
80
E Put the combustion chamber back into its place. The combustion chamber
is positioned correctly when it can be smoothly moved a little to the left
and to the right by its handle E (Fig. F). Close the grill: Slightly lift it to
reposition it in its slot.
E Open the lid of the removable tank 4 and remove the piece of polyfoam.
3
Fill the removable tank as indicated in Section B.
4
Insert the batteries into their holder L at the back of the heater (Fig. G).
Ensure that the positive and negative poles match the + and - marks indicated
on the battery housing. Close the battery cover.
E Do not mix the + and the - pole
E Do NOT recharge non rechargeable batteries!
E Do NOT mix different types and brands of batteries, do NOT mix old and
new batteries"
E If the appliance is stored or not used for a longer period: always remove
the batteries
E Do NOT short circuit the electrical power supply terminals
E To remove the batteries: simply remove them from the battery enclosure
5
The floor should be firm and completely level. Reposition the heater, when it is
not level. Do not correct the situation by placing books or other goods under the
heater. Please refer to the separate instructions in the carton box for fixing of
the heater.
6
Your heater is now ready for use.
FILLING FUEL
Fill the removable tank in a suitable place since there can always be some spillage.
Follow the procedure below:
1
Make sure that the heater is switched off.
2
Open the upper lid and lift the removable tank out of the heater (Fig. H).
Note: Some drops may leak from the tank. Put down the removable tank (cap
pointing upwards, handle on floor and screw off the fuel cap.
3
Fill the removable tank using a fuel pump (refer to fuel pump operation
instructions.) Make sure that it is in a higher position than the removable tank
(Fig. I). Insert the ribbed hose into the opening of the removable tank.
4
Check the removable tank fuel gauge while filling the tank (Fig. J). Stop filling
once the gauge indicates that the tank is full. Never overfill the tank,
especially not when the fuel is very cold (fuel expands when it heats up).
5
Let the remaining fuel in the pump flow back into the jerry can and carefully
remove the pump. Carefully screw the fuel cap back on the tank. Clean off
any spilled fuel.
6
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.