Kenmore 1500e Serie Manual De Uso Y Cuidado página 13

Idiomas disponibles

Idiomas disponibles

The outer surface of the filter should be
cleaned every 2–4 weeks to increase
efficiency and extend the life of the
composite filter.
When the filter life will expire, the last
frame of filter life indicator bars will flash
to remind user to replace the filters. It is
recommended to replace the composite
filter every 6 months.
1. Unplug the air purifier. Remove the
filter covers as outlined in ASSEMBLY
INSTRUCTIONS (page 8).
2. Remove the old filters from inside the air
purifier.
3. Clean the outer surface of the filter using
a soft cloth to remove hair, dust, and
large particles.
NOTE: Do not clean the filter with water or
other liquids.
ONLY clean the pre-filter surface. Do not
clean the HEPA filter, and activated carbon
filter.
CLEANING & REPLACING FILTERS
4. Clean out any remaining dust or hair
inside the air purifier using a vacuum
hose. Do not use water or liquids to
clean the air purifier.
5. Replace the cleaned filters back
into the air purifier. See ASSEMBLY
INSTRUCTIONS (page 8).
6. If required, replace with new filters.
Unwrap the new filters from the
packaging and install them into the air
purifier. See page 6 for instructions on
how to order new filters.
7. Install the filter covers back into the air
purifier. See ASSEMBLY INSTRUCTIONS
(page 9).
8. Plug in the air purifier. Reset the filter life
as outlined in Filter Reset Button (page 11).
- 13 -
loading

Este manual también es adecuado para:

Pm3020