PNI C130 Manual De Usuario página 11

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
The charger does
F05
not enter the "float"
mode in 24 hours.
F06
Polarity reversed.
The charging voltage
F07
is too high during the
alternator test.
The charging voltage
F08
is too low during the
alternator test.
Technical specifications
Supply voltage
Charging voltage
The charging current
Compatible battery
Dimensions
Weight
11
The charging current
is too low.
A consumer is
connected to the
battery.
The battery is
defective.
The charger clamps
were connected
incorrectly.
The charger is poorly
functional.
The alternator is
poorly functional.
220-240VAC, 50Hz
7.2V / 14.4V / 28.8V (standard battery)
2A/4A/8A/12A(6V/12V)
1A/2A/4A/6A (24V)
Lithium batteries with BMS, colloidal
batteries, EFB, AGM and calcium batteries,
GEL batteries
25 - 300Ah (during charging)
195 x 138 x 78 mm
1.51 kg
Disconnect the
charger from the
AC source, restart
and select a higher
charging current.
Remove the
consumer from the
battery.
Replace the battery.
Reconnect the pliers
correctly.
Check the charger.
Check the alternator.
User manual
loading