Error codes
Code Details
The battery voltage
F01
is below 12V, after a
charge of 300 min.
If after 20 hours
(five times in
reconditioning
mode), due to a
F01
defective battery,
the battery does
not enter the "float"
stage
Error of battery
F02
type.
Battery charger
F03
short circuit.
Charger temperature
F04
is too high.
User manual
Reason
The battery is
defective or
a consumer is
connected to the
battery.
The battery is
sulfated after
reconditioning.
Battery voltage
mismatch.
Battery clip short
circuit.
The charger is
located in a location
with too high a
temperature and no
ventilation.
Action
Replace the battery.
Disconnect the
consumer from the
battery.
Replace the battery.
Replace the battery.
Check the clip for
short circuit.
Select a lower
charging current to
continue charging or
wait 30 minutes for
the charger to cool
down. Ensure a space
of at least 10 cm
around the charger.
for its ventilation.
10