AXIS A1210 Network Door Controller
System considerations
Maintenance instructions
Further information
Power
-
External power to relays - If the relays are
connected to an external power source this must
be UL 294 listed Class 2 low-voltage power SELV
and limited power supply.
-
Network Connector – Standard Ethernet
wiring. Evaluated by UL when powered from
AXIS T8133 Midspan 30 W 1-port in PoE Mode B
(alternative A).
-
Supervised inputs were not evaluated by UL for
burglar use.
-
Monitoring software was not evaluated by UL, and
is for supplemental use.
-
For maintenance instructions and for information
about how to configure the Axis product, see the
User Manual.
-
Card formats verified by UL: ISO Cards Mifare 1K,
32 bits.
-
Power in: 12 V DC, max 36 W.
Power over Ethernet (PoE) IEEE 802.3at,
Type 2 Class 4
-
Relay: 1x relay NO/NC, max 2 A DC
-
Power out lock: 19.2 W if powered by DC, 10.8 W if
powered by PoE Class 4
-
Power out reader: 12 V DC, max 6 W
-
Auxiliary DC output: 1x 12 V DC output, max
200 mA
-
Total power budget for peripheral devices (locks,
readers etc.): 2100 mA at 12 V if powered by DC,
1400 mA at 12 V if powered by PoE Class 4