GYS GYSFLASH 8.12 PL Manual De Instrucciones página 13

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Operating manual
DEFECTS: CAUSES & SOLUTIONS
Troubleshooting
1
The indicator
blinks rapidly.
2
The indicator
blinks slowly.
3
The indicator
is on.
The indicator
stays on even after pres-
4
sing the button
5
The indicator
flashes.
6
The light
stays on.
WARRANTY CONDITIONS
The warranty covers any defects or manufacturing faults for two years from the date of purchase (parts and labour).
The warranty does not cover:
• Any other damage caused by transport.
• The general wear and tear of parts (i.e. : clamps, etc.).
• Incidents caused by misuse (incorrect power supply, dropping or dismantling).
• Environment-related faults (such as pollution, rust and dust).
In the event of a breakdown, please return the appliance to your distributor, along with:
- a dated proof of purchase (receipt or invoice etc.).
a note explaining the malfunction.
Translation of the original
instructions
Causes
• Polarity reversal
• Battery voltage too high
• Short-circuited clamps
Battery out of order or very low voltage.
Failure during charging, battery not
recoverable.
Thermal protection
Charger in sleep mode.
Charging interrupted by pressing the
button
.
GYSFLASH 8.12 PL
Solutions
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
Change the battery.
Change the battery and press
charge.
Ambient temperature is too high (>60°C), cool the
room and let the charger cool down.
Press the
button or connect a battery to the
charger to wake up from standby.
Press again
to restart the charge.
to restart a
13