Operating manual
• Lithium charging curve:
The Gysflash 8.12 PL uses an advanced 8-stage Lithium charging curve that ensures optimal performance of your LFP battery.
1
U
I
Analyse
< 1s
CHARGE
OK
1
Step
: Analysis
Analysis of the battery status (level of charge, reverse pola-
rity, incorrect battery connected...)
2
Step
: Recovery (0.2A - 1A)
Recovery process after deep discharge.
3
Step
: Charge (4A - 8A)
Fast charge at maximum current to reach 90% charge level.
4
Step
: Absorption (13.8V)
Constant voltage load to bring the charge level to 98%.
• Estimated charge time
Battery capacity
2Ah
Charge time
2 h
0% >> 90%
*Lead acid battery equivalent: Lithium batteries have better starting performance (CCA) than lead-acid batteries. This is why some
lithium battery manufacturers indicate the lead battery equivalent (EqPb) corresponding to the capacity of a lead-acid battery with
the same starting performance. For instance, a 10Ah LFP battery will have approximately the same starting performance as a 30
Ah lead-acid battery.
If the motorcycle is equipped with a 12V socket, the GYSFLASH 8.12 PL is able to charge the battery via this socket
with the CAN-BUS system, without having to switch on the dashboard. In this setup, connect the cigratte lighter
adapter (ref. 077331) on the charger and the 12 V socket of the motorcycle and then follow the «Start-up» procedure
detailed above. In some cases, charging may not start until 2 minutes after the connections have been made.
- Protections :
The GYSFLASH 8.12 PL has comprehensive safety features to protect it against short-circuits and polarity rever-
sals. It has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has
double insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 8.12 PL is fitted with an integrated temperature sensor that ensures that the charging current is adapted to the
ambient temperature to prevent internal the electronics from overheating.
12
Translation of the original
instructions
2
3
Récupération
Charge
Absorption
Max 5 min
Max 30 h
Lead-acid
5Ah
50 Ah
100 Ah 120 Ah 160 Ah
3 h
5 h
9 h
11 h
4
5
6
Equalizing Battery System
Test
Complément
Max 20 h
3 min
Max 10 h
5
Step
: Test
Charge retention test
6
Step
: Completion
Reduced current charging to reach 100% level of charge.
7
Step
: Equalization / balancing (14.4V)
Balancing the battery cells
8
Step
: Maintenance charge (13.8V)
Maintain the battery charge level at its maximum with mainte-
nance charging every 10 days.
2Ah
15 Ah
(6Ah EqPb*)
(45Ah EqPb*)
14 h
1 h
3 h
GYSFLASH 8.12 PL
7
8
Egalisation /
Maintien de
charge
équilibrage
Max 2 h
No limit
(maintenance tous les 10 jours)
Lithium
50 Ah
70 Ah
125 Ah
(150Ah EqPb*)
(210Ah EqPb*)
(375Ah EqPb*)
5 h
6 h
11 h
160 Ah
(480Ah EqPb*)
14 h
loading