Table continued from last page
Error name
Err 005
Err 006
Err 007
Err 008
Err 014
Err 015
EN 42
Description
Possible cause
Overheating of
Ambient
user interface
temperature is too
high, NTC sensor
is malfunctioning.
Self Clean door
Door lock on the
lock failure
appliance is
malfunctioning.
Failure of power
Failure of power
board relay
supply.
supply
Overheating of
Ambient
power board
temperature is too
high, NTC sensor
is malfunctioning.
Cooktop
Cooktop was
activation during
activated while
active Self Clean
the Self Clean
function
function was
active.
Zero cross failure
Failure on
on power board
electronics.
Solution
Check ambient temperature in the
room. Cool down the appliances.
Disconnect the cooking range from the
power mains for a few minutes (undo
the fuse or switch off the main switch);
then, reconnect the cooking range to
the power main. If the problem
persists, contact service.
Check position of pots. Pots position
might influence temperature on the
user interface.
Stop Self Clean function, wait until the
door is unlocked and start it again. If
the problem persists, contact service.
Check correct voltage in house
installation. Disconnect the cooking
range from the power mains for a few
minutes (undo the fuse or switch off
the main switch); then, reconnect the
cooking range to the power mains. If
the problem persists, contact service.
Check ambient temperature in the
room. Cool down the appliances.
Disconnect the cooking range from the
power mains for a few minutes (undo
the fuse or switch off the main switch);
then, reconnect the cooking range to
the power mains. If the problem
persists, contact service.
Turn off any active cooktop heater and
start Self Clean function again.
Disconnect the cooking range from the
power mains for a few minutes (undo
the fuse or switch off the main switch);
then, reconnect the cooking range to
the power mains. If the problem
persists, contact service.