Warning (for R290)
Specific information regarding appliances with R290 refrigerant gas.
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance, do not use any tools other than those recommended
by the manufacturing company.
The appliance must be placed in an area without any continuously sources of ignition (for example:
open flames, gas or electrical appliances in operation).
Do not puncture and do not burn.
This appliance contains Y g (see rating label back of unit) of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the European directives on the environment. Do not
puncture any part of the refrigerant circuit.
If the appliance is installed, operated or stored in an unventilated area, the room must be designed
to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to
ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
The appliance must be stored in such a way as to prevent mechanical failure.
Individuals who operate or work on the refrigerant circuit must have the appropriate certification
issued by an accredited organization that ensures competence in handling refrigerants according to
a specific evaluation recognized by associations in the industry.
Repairs must be performed based on the recommendation from the manufacturing company.
Maintenance and repairs that require the assistance of other qualified personnel must be performed
under the supervision of an individual specified in the use of flammable refrigerants.
Ducts connected to an appliance shall not contain a potential ignition source.
General Safety Instruction
1. The appliance is for indoor use only.
2. Do not use the unit on a socket under repairs or not installed properly
3. Do not use the unit, follow these precautions:
A: Near to source of fire.
29