Holmatro GCU 50 i EVO 3 Manual página 37

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 94
Position and color of the LED
green
green
green
green
green
green blinking -
green
-
green
-
blinking
3.6.2
Condition of the battery pack
The Battery Management System (BMS) protects the battery pack against internal damage. The
following LED combinations show the condition of the battery pack and the proposed action/ solution.
/i
Position and color of the LED
1
2
red
-
red
green
red
green
red /
-
green
red /
-
green
3.7
Technical specifications battery pack
/i
Description
voltage
capacity
energy
battery type
weight, ready for use
temperature range
3.8
Safety features of the battery pack
The battery pack is protected against:
Short-circuit
Deep discharge
Over- and under-voltage (of the battery pack and the individual cells)
Over-current during charging and discharging
Overcharging
Over temperature (of individual cells and electronics)
Charging and discharging outside the allowed temperature range
GCU 50* (i) EVO 3
All manuals and user guides at all-guides.com
green blinking -
-
-
-
3
4
-
green
green
-
green
green
-
-
-
green
Unit
VDC
Ah
Wh
kg
lb
°C
°F
916.001.652_002
SOC
> 37%
≥ 25%
-
≥ 12%
-
≥ 5%
-
-
< 5%
Condition
Under voltage
Electronics over
temperature
Cells over temperature
Cells under temperature
Under voltage and under
temperature
BPA285
BPA286
28
5
126
Li-Ion
1
2.2
-20 + 55
-4 + 131
Action / Solution
Use battery pack
Charge battery pack
Charge battery pack
Charge battery pack
Charge battery pack
Action / Solution
Charge battery pack
Cool battery pack
Cool battery pack
Warm battery pack
Charge and warm
battery pack
28
6
151
EN
37
loading

Este manual también es adecuado para:

Gcu 50 evo 3