T.I.P. TAF 5000 UV 7 Instrucciones Para El Manejo página 16

Old UV-C tubes shall not get broken and must not be disposed in regular garbage bin. Contact your local waste disposal
company. Do not use an sharp edged tools. In case Quartz glass cylinder or O-ring are defect, they should get replaced
immediately.
Fig.I
Function check of UVC lamp
In case the UVC lamp does not shine, the micro switch might not be activated. The UVC lamp should get completely
reassembled.
1. Assemble UV-C tube (2) including Quartz glass (3) to lamp socket (1).
2. Make sure O Ring (4) is inserted
3. Pull the protective housing (5) over the UV-C tube and Quartz glass and connect to the socket. By doing so the micro
switch should get active automatically.
The UVC tube works properly if you see a bluish light at the end of the lamp socket (1).
6.3.
Cleaning of filter
Replace all filter mats (10) regularly(1 x pro Saison)
If you discover a deterioration of the water quality or too low flow rate or water coming out of the lid of the filter, the
following steps should be done:
1) On the bottom of the filter housing (12) larger amounts of dirt particles get collected over the time. These must be
removed
2) Mechanical sponge filter: Take the sponges (10) out of the filter and clean them with clear water. Insert the sponges
in the correct horizontal position above the bioballs (11).
3) Biological Filter: the Bioballs (11) should be rinsed out, if the amount of debris has increased strongly
Annual maintenance: Carefully clean the filter at least once per year.
Empty the filter completely. Remove the dirt and debris from the bottom. Rinse out all filter materials with water.
6.4.
Winter - maintenance
Protect your pond filter from freezing!
If there is danger of freezing, take the pump out of your garden pond.
Completely clean the pump as specified in the instructions.
Store the pump over winter in a frost-free location
7. Warranty
The present device was manufactured and inspected according to the latest methods. The seller warrants for faultless
material and workmanship in accordance with the legal regulations of the country in which the device was purchased.
The warranty period begins with the day of the purchase and is subject to the provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will be
eliminated free of charge. Any complaints are to be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties. Damage
resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection or installation or
Acts of God or other external influences are excluded from warranty.
Parts subject to wear, such as the UV–C tube, rotor and bearings are excepted from the guarantee. All parts were
manufactured using maximum care and high-quality materials and are designed for a long lifecycle. It should be
understood, however, that the wear and tear depends on the kind of use, the intensity of use and the internals of
maintenance. Complying with the installation and maintenance information contained in the present operating
instructions will therefore considerably contribute to a long lifecycle of these wearing parts.
In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire device.
Replaced parts will pass into our property.
Claims for liquidated damages are excluded unless they are caused by willful acts or negligence on the side of the
manufacturer.
The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be evidenced
by the purchaser in the form of the submission of the sales receipt. The present warranty commitment is valid in the
country in which the device was purchased.
Please note:
14
Fig.II
5
Fig.III
loading