2. Range of use
Garden pumps from T.I.P. are highly efficient self-priming electrical pumps for discharging clear, clean or
moderately dirty water containing solids up to the maximum size specified in the technical details. These high-
quality products with their convincing performance data were developed for the multiple purposes involved with
irrigation, draining, water withdrawal as well as for the further conveyance of water under pressure.
The typical ranges of application of garden pumps include: filling or emptying of storage containers, basins and
ponds, water withdrawal from wells or cisterns, flushing down of terraces and boardwalks.
The device is not suitable for use in swimming pools or for installation in public water mains.
This product is intended for private use in the home area and not for commercial or industrial purposes or for
continuous circulating.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. and min. temperatures of the liquids to be
discharged stated in the technical data.
3. Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Suction port
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. suction height
Max. size of the solids being pumped
Max. permissible operating pressure
Min. ambient temperature
Max. ambient temperature
Min. fluid temperature
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Guaranteed sound power level (L
Measured sound power level (L
2)
Sound pressure level (L
)
pA
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced in- an outlet.
2)
Noise emission values obtained according to the EN 12639 regulation. Measurement method according to
EN ISO 3744.
4. Scope of delivery
The scope of the delivery of this product includes:
One pump with connection cable, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation", "Automation with special
accessories" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
9
2)
)
WA
2)
)
WA
GPK 3600
230 V~ / 50 Hz
650 Watt
IPX4
(1 ")
33.25 mm
(1 ")
33.25 mm
3.600 l/h
4 bar
40 m
9 m
3 mm
6 bar
5 °C
40 °C
2 °C
35 °C
40, evenly distributed
1.5 m
H07RN-F
5.6 kg
81 dB
79,2 dB
64,9 dB
35 x 18 x 23 cm
30147
2
, male
, male