Mitsubishi Electric MSZ-BT20VG Manual De Instrucciones página 9

Ocultar thumbs Ver también para MSZ-BT20VG:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
S
PECIFICATIONS
Indoor
Model
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/
High/Med./Low/Silent)
Noise level (SPL)
Outdoor
Indoor specifi cation for multi connection
Model
Indoor
Cooling
Capacity
Heating
Input
Noise level
Super High/High/Med./Low/
(Sound power level)
Silent
Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
27°C DB
Upper limit
Heating
20°C DB
Lower limit
Wi-Fi interface
Model
Input Voltage
Power consumption
Size H×W×D (mm)
Weight (g)
Transmitter power level (MAX.)
RF channel
Radio protocol
Encryption
Authentication
Software Version
For Declaration of Conformity, please go to the website below.
http://www.melcloud.com/Support
MSZ-BT20VG(K)
MUZ-BT20VG
Cooling
Heating
2.0
2.5
kW
0.45
0.55
kW
kg
23
kg
0.45
kg
MPa
MPa
43/37/30/
43/37/30/
dB(A)
22/19
23/20
50
50
dB(A)
REGULATION (EU) 2016/2281
MSZ-BT20VG(K)
Sensible
kW
1.98
Latent
kW
0.02
kW
2.50
kW
0.024
dB(A)
57/51/44/36/33
Outdoor
46°C DB
-10°C DB
24°C DB
18°C WB
-15°C DB
DB: Dry Bulb
-16°C WB
WB: Wet Bulb
MAC-577IF-E
DC12.7 V (from indoor unit)
MAX. 2 W
73.5×41.5×18.5
46 (including cable)
20 dBm @IEEE 802.11b
1ch ~ 13ch (2412~2472 MHz)
IEEE 802.11b/g/n (20)
AES
WPA2-PSK
XX.00
MSZ-BT25VG(K)
MSZ-BT35VG(K)
MUZ-BT25VG
MUZ-BT35VG
Cooling
Heating
Cooling
~ /N, 230 V, 50 Hz
2.5
3.15
3.5
0.70
0.75
1.24
9.0
24
0.50
IP 20
IP 24
2.77
4.17
43/37/30/
43/37/30/
46/38/31/
22/19
23/20
22/19
50
50
52
MSZ-BT25VG(K)
MSZ-BT35VG(K)
2.30
2.94
0.20
0.56
3.15
3.60
0.024
0.031
57/51/44/36/33
60/52/45/36/33
Note:
Rating condition
Cooling — Indoor:
Outdoor: 35°C DB
Heating — Indoor:
Outdoor: 7°C DB, 6°C WB
W
HEN YOU THINK THAT
TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/
OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
MSZ-BT50VG(K)
MUZ-BT50VG
Heating
Cooling
Heating
3.6
5.0
5.4
0.93
2.05
1.55
35
0.70
44/37/30/
46/40/36/
48/43/38/
23/20
33/29
33/29
52
50
51
MSZ-BT50VG(K)
3.65
1.35
5.40
0.037
60/54/50/47/43
27°C DB, 19°C WB
20°C DB
EN-7
EN
loading