NOTE:
When installing Motor Assembly #62, orient the motor
with the slot in the motor canister to the bottom
and the positive terminal (marked with a
red dot) to the inside of Left Handle
Halve #40. Solder the red wire from
the top left position of the switch
to the positive motor terminal.
Solder the black wire from the
top right position of the switch
to the negative terminal on motor.
MOTOR
ASSEMBLY #62
PRINTED CIRCUIT
BOARD ASSEMBLY
(PCBA) #37
+
Black switch wire
Red switch
wire
Slot
BATTERY
CONTACT
PLATE #36
AS AN AID TO REASSEMBLY, TAKE NOTICE OF WIRE
ROUTING AND POSITION IN WIRE GUIDES AND
TRAPS WHILE DISMANTLING TOOL.
BE CAREFUL AND AVOID PINCHING WIRES
BETWEEN HANDLE HALVES WHEN ASSEMBLING.
= WIRE TRAPS
or GUIDES
LED LENS #44
ON/OFF
SWITCH #34